HAC-62 < COMPONENT DIAGNOSIS > [AUTOMATIC AIR CONDITIONER] POWER SUPPLY AND GROUND CIRCUIT FOR FRONT AIR CONTROL SYMPTOM: A/C system does not come on. 1. CHECK POWER SUPPLY CIRCUIT FOR FRONT AIR CONTROL 1. Disconnect front air control connector M37. 2. Press ignition switch ON. 3. Check voltage between front air control connector M37 termi- nals 19, 39 and 40, and ground. Is the inspection result normal? YES >> GO TO 2 NO >> Check the following. • 10A fuses [Nos. 6, 19, and 3, located in the fuse block (J/B)]. • If fuses are OK, check for open circuit in wiring harness. Repair or replace as necessary. • If fuses are NG, replace fuse and check wiring harness for short circuit. Repair or replace as necessary. 2. CHECK BODY GROUND CIRCUIT FOR FRONT AIR CONTROL 1. Press ignition switch OFF. 2. Check continuity between front air control connector M37 termi- nals 17and 37 and ground. Is the inspection result normal? YES >> • Replace front air control. Refer to VTL-8, "Removal and Installation" . • Inspection End. NO >> Repair or replace harness. AWIIA0642GB Terminals Voltage (V) (Approx.) (+) (-) Connector - Terminal Body ground 12V M37-19 M37-39 M37-40 AWIIA0613ZZ Terminal Continuity (+) (-) Connector - Terminal Body ground Yes M37-17 M37-37 AWIIA0620ZZ |