Content .. 1577 1578 1579 1580 ..
HAZARD WARNING LAMPS FLASH WT-59 < SYMPTOM DIAGNOSIS > C D F G H I J K L M A B WT N O P HAZARD WARNING LAMPS FLASH Hazard Warning Lamps Flash When Ignition Switch Is Turned On INFOID:0000000004205319 DIAGNOSTIC PROCEDURE 1. CHECK BCM GROUND CIRCUIT Check BCM ground circuit. Refer to . Is the inspection result normal? YES >> Replace BCM. Refer to BCS-96, "Removal and Installation" NO >> Repair BCM ground circuit. |