Content .. 1167 1168 1169 1170 ..
RF-18 < COMPONENT DIAGNOSIS > DOOR SWITCH Is the inspection result normal? YES >> GO TO 4 NO >> GO TO 2 2. CHECK DOOR SWITCH CIRCUIT 1. Disconnect BCM connector. 2. Check continuity between BCM connector and door switch con- nector. 3. Check continuity between BCM connector and ground. Is the inspection result normal? YES >> GO TO 3 NO >> Repair or replace harness between BCM and door switch. 3. CHECK DOOR SWITCH . Is the inspection result normal? YES >> GO TO 4 NO >> Replace malfunctioning door switch. 4. CHECK INTERMITTENT INCIDENT GI-42, "Intermittent Incident" Terminals Door condition Voltage (V) (Approx.) (+) (–) BCM connector Terminal M18 58 Ground Driver side OPEN 0 CLOSE 32 Passenger side OPEN 0 CLOSE JPMIA0011GB JPMIA0011GB BCM connector Terminal Door switch connector Terminal Continuity A: M18 58 B: B8 (Driver side) 2 Yes 32 B: B108 (Passenger side) BCM connector Terminal Ground Continuity A: M18 58 No 32 ALKIA1040ZZ |