Content .. 1000 1001 1002 1003 ..
PCS-72 < COMPONENT DIAGNOSIS > [POWER DISTRIBUTION SYSTEM] B2616 IGNITION RELAY CIRCUIT 1. Turn ignition switch OFF. 2. Disconnect BCM harness connector. 3. Check continuity between ignition relay harness connector (A) and BCM harness connector (B). 4. Check continuity between ignition relay harness connector (A) and ground. Is the inspection result normal? YES >> GO TO 6 NO >> Repair or replace harness. 3. CHECK IGNITION RELAY GROUND CIRCUIT 1. Turn ignition switch OFF. 2. Check continuity between ignition relay harness connector and ground. Is the inspection result normal? YES >> GO TO 4 NO >> Repair or replace harness. 4. CHECK IGNITION RELAY POWER SUPPLY CIRCUIT-2 Check voltage between ignition relay harness connector and ground. Is the inspection result normal? YES >> GO TO 5 NO >> Repair or replace harness. 5. CHECK IGNITION RELAY PCS-73, "Component Inspection (Ignition Relay)" . Is the inspection result normal? YES >> GO TO 6 NO >> Replace ignition relay. 6. CHECK INTERMITTENT INCIDENT GI-42, "Intermittent Incident" >> Inspection End. Ignition relay BCM Continuity Terminal Connector Terminal 1 M19 70 Yes Ignition relay Ground Continuity Terminal 1 Ground No ALMIA0447ZZ Ignition relay Ground Continuity Terminal 2 Ground Yes ALMIA0448ZZ Ignition relay Ground Voltage (V) Terminal 5 Ground Battery voltage ALMIA0449ZZ |