SEC-6 < BASIC INSPECTION > PRE-INSPECTION FOR DIAGNOSTIC PRE-INSPECTION FOR DIAGNOSTIC Basic Inspection INFOID:0000000006161550 1. INSPECTION START Turn ignition switch “OFF”. NOTE: Before starting operation check, open front windows. >> GO TO 2. 2. CHECK SECURITY INDICATOR LAMP 1. Lock doors using keyfob or ignition key. 2. Check that security indicator lamp illuminates for 30 seconds. YES >> GO TO 3. NO >> Perform diagnosis and repair. Refer to SEC-35, "Component Function Check" . 3. CHECK ALARM FUNCTION 1. After 30 seconds, security indicator lamp will start to blink. 2. Open any door before unlocking with keyfob or ignition key. YES >> GO TO 4. NO >> Check the following. • The vehicle security system does not phase in alarm mode. Refer to . • Alarm (horn and headlamp do not operate. Refer to 4. CHECK ALARM CANCEL OPERATION Unlock driver door using keyfob or ignition key. YES >> Inspection End. NO >> Check door lock function. Refer to DLK-12, "DOOR LOCK AND UNLOCK SWITCH : System . |