SUNSHADE SYSTEM DOES NOT OPERATE PROPERLY RF-137 < SYMPTOM DIAGNOSIS > [WITH DUAL PANEL SUNROOF] C D E F G H I J L M A B RF N O P SUNSHADE SYSTEM DOES NOT OPERATE PROPERLY Diagnosis Procedure INFOID:0000000010049006 1. CHECK SUNSHADE MECHANISM Check the following. • Operation malfunction caused by sunshade mechanism deformation, pinched harness or other foreign materials • Operation malfunction and interference with other parts by poor installation YES >> GO TO 2. NO >> Repair or replace the malfunctioning parts. 2. CHECK SUNSHADE MOTOR ASSEMBLY POWER SUPPLY AND GROUND CIRCUIT Check sunshade motor assembly power supply and ground circuit. RF-85, "SUNSHADE MOTOR ASSEMBLY : Diagnosis Procedure" Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace the malfunctioning parts. 3. CHECK COMMUNICATION CIRCUIT Check communication circuit. Is the inspection result normal? YES >> GO TO 4. NO >> Repair or replace the harness. 4. CONFIRM THE OPERATION Confirm the operation again. YES >> Check intermittent incident. Refer to GI-41, "Intermittent Incident" . NO >> GO TO 1. |