DIAGNOSTIC PROCEDURE 3 =NMEL0055S06 1 CHECK IGNITION ON SIGNAL 1. Disconnect combination meter harness connector. SEL216Y OK or NG OK © GO TO 2. NG © Check the following. I 10A fuse [No. 11, located in fuse block (J/B)] I Harness for open or short between combination meter and fuse 2 CHECK DOOR SWITCH INPUT SIGNAL 1. Connect combination meter harness connector. SEL232Y OK or NG OK © Driver side door switch is OK. NG © GO TO 3. GI MA EM LC EC FE CL MT AT PD AX SU BR ST RS BT HA SC IDX WARNING BUZZER Trouble Diagnoses (Cont’d) EL-85 |