CONSULT-II Reference Value in Data Monitor NMEC0773 Specification data are reference values. MONITOR ITEM CONDITION SPECIFICATION START SIGNAL I Ignition switch: ON , START , ON OFF , ON , OFF ECM Terminals and Reference Value NMEC0774 Specification data are reference values and are measured between each terminal and ground. CAUTION: Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam- TERMI- NAL NO. WIRE COLOR ITEM CONDITION DATA (DC Voltage) 34 OR/L Start signal [Ignition switch “ON”] Approximately 0V [Ignition switch “START”] 9 - 12V GI MA EM LC FE CL MT AT PD AX SU BR ST RS BT HA SC EL IDX START SIGNAL CONSULT-II Reference Value in Data Monitor Mode EC-199 |