PWC-38 < SYMPTOM DIAGNOSIS > AUTO OPERATION DOES NOT OPERATE NORMALLY AUTO OPERATION DOES NOT OPERATE NORMALLY POWER WINDOW MAIN SWITCH IS OPERATED POWER WINDOW MAIN SWITCH IS OPERATED : Diagnosis Procedure INFOID:0000000009159957 1. PERFORM INITIALIZATION PROCEDURE Perform initialization of power window that is malfunctioning, and check that auto operation operates normally. PWC-4, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special . Is the inspection result normal? YES >> INSPECTION END NO >> GO TO 2. 2. CHECK POWER WINDOW AUTO CIRCUIT (POWER WINDOW MAIN SWITCH) Check power window auto circuit (power window main switch). PWC-22, "POWER WINDOW MAIN SWITCH : Component Function Check" Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace the malfunctioning parts. 3. CONFIRM THE OPERATION Confirm the operation again. Is the inspection result normal? YES >> Check intermittent incident. Refer to GI-38, "Intermittent Incident" . NO >> GO TO 1. POWER WINDOW SUB-SWITCH IS OPERATED POWER WINDOW SUB-SWITCH IS OPERATED : Diagnosis Procedure INFOID:0000000009159958 1. PERFORM INITIALIZATION PROCEDURE Perform initialization of power window that is malfunctioning, and check that auto operation operates normally. PWC-4, "ADDITIONAL SERVICE WHEN REMOVING BATTERY NEGATIVE TERMINAL : Special . Is the inspection result normal? YES >> INSPECTION END NO >> GO TO 2. 2. CHECK POWER WINDOW AUTO CIRCUIT (POWER WINDOW SUB-SWITCH) Check power window auto circuit (power window sub-switch). PWC-25, "POWER WINDOW SUB-SWITCH : Component Function Check" Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace the malfunctioning parts. 3. CONFIRM THE OPERATION Confirm the operation again. YES >> Check intermittent incident. Refer to GI-38, "Intermittent Incident" . NO >> GO TO 1. |