Nissan Pathfinder. Manual - part 499

 

  Index      Nissan     Nissan Pathfinder (2014 year) - Service and Repair Manual

 

Search            

 

 

 

 

 

 

 

 

 

Content   ..  497  498  499  500   ..

 

 

Nissan Pathfinder. Manual - part 499

 

 

EC-302

< DTC/CIRCUIT DIAGNOSIS >

[VQ35DE]

P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID 

VALVE

P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID
VALVE

DTC Logic

INFOID:0000000009178209

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

CONDITIONING

If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-

ing the next test.

1. Turn ignition switch OFF and wait at least 10 seconds.

2. Turn ignition switch ON.

3. Turn ignition switch OFF and wait at least 10 seconds.

TESTING CONDITION:

Before performing the following procedure, confirm battery voltage is more than 11 V at idle.

>> GO TO 2.

2.

PERFORM DTC CONFIRMATION PROCEDURE

1. Start engine and let it idle for at least 13 seconds.

2. Check 1st trip DTC.
Is 1st trip DTC detected?

YES

>> Proceed to 

EC-303, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000009178210

1.

CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY

1. Turn ignition switch OFF.

2. Disconnect EVAP canister purge volume control solenoid valve harness connector.

3. Turn ignition switch ON.

4. Check the voltage between EVAP canister purge volume control solenoid valve harness connector and

ground.

Is the inspection result normal?

YES

>> GO TO 2.

NO

>> Perform the trouble diagnosis for power supply circuit.

2.

CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT

DTC No.

CONSULT screen terms

(Trouble diagnosis content)

DTC detecting condition

Possible cause

P0444

PURG VOLUME CONT/V
(Evaporative emission system 
purge control valve circuit open)

An excessively low voltage signal is 
sent to ECM through the valve

• Harness or connectors

(The solenoid valve circuit is open or 
shorted.)

• EVAP canister purge volume control so-

lenoid valve

P0445

PURG VOLUME CONT/V
(Evaporative emission system 
purge control valve circuit shorted)

An excessively high voltage signal is 
sent to ECM through the valve

• Harness or connectors

(The solenoid valve circuit is shorted.)

• EVAP canister purge volume control so-

lenoid valve

EVAP canister purge volume control 

solenoid valve

Ground

Voltage

Connector

Terminal

F16

1

Ground

Battery voltage

P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID 

VALVE

EC-303

< DTC/CIRCUIT DIAGNOSIS >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

1. Turn ignition switch OFF.

2. Disconnect ECM harness connector.

3. Check the continuity between EVAP canister purge volume control solenoid valve harness connector and

ECM harness connector.

4. Also check harness for short to ground and short to power.
Is the inspection result normal?

YES-1 >> With CONSULT: GO TO 3.

YES-2 >> Without CONSULT: GO TO 4.

NO

>> Repair open circuit, short to ground or short to power in harness or connectors.

3.

CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OPERATION

With CONSULT

1. Reconnect all harness connectors disconnected.

2. Start engine.

3. Perform “PURG VOL C/V” in “ACTIVE TEST” mode with CONSULT. Check that engine speed varies

according to the valve opening.

Does engine speed vary according to the valve opening?

YES

>> Check intermittent incident. Refer to 

GI-49, "Intermittent Incident"

.

NO

>> GO TO 4.

4.

CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE

Check EVAP canister purge volume control solenoid valve. Refer to 

EC-304, "Component Inspection"

.

Is the inspection result normal?

YES

>> Check intermittent incident. Refer to 

GI-49, "Intermittent Incident"

.

NO

>> Replace EVAP canister purge volume control solenoid valve. Refer to 

EC-14, "ENGINE CON-

TROL SYSTEM : Component Parts Location"

.

Component Inspection

INFOID:0000000009178211

1.

CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE

With CONSULT

1. Turn ignition switch OFF.

2. Reconnect all harness connectors disconnected.

3. Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.

4. Turn ignition switch ON.

5. Select “PURG VOL C/V” in “ACTIVE TEST” mode with CONSULT.

6. Touch “Qd” and “Qu” on CONSULT screen to adjust “PURG

VOL C/V” opening and check air passage continuity of EVAP

canister purge volume control solenoid valve under the following

conditions.

Without CONSULT

1. Turn ignition switch OFF.

2. Disconnect EVAP canister purge volume control solenoid valve harness connector.

3. Disconnect EVAP purge hoses connected to EVAP canister purge volume control solenoid valve.

EVAP canister purge volume con-

trol solenoid valve

ECM

Continuity

Connector

Terminal

Connector

Terminal

F16

2

F51

42

Existed

Condition

(PURG VOL C/V value)

Air passage continuity 

between  

and 

100%

Existed

0%

Not existed

PBIB2058E

EC-304

< DTC/CIRCUIT DIAGNOSIS >

[VQ35DE]

P0444, P0445 EVAP CANISTER PURGE VOLUME CONTROL SOLENOID 

VALVE

4. Check air passage continuity of EVAP canister purge volume

control solenoid valve under the following conditions.

Is the inspection result normal?

YES

>> INSPECTION END

NO

>> Replace EVAP canister purge volume control solenoid valve. Refer to 

EC-14, "ENGINE CON-

TROL SYSTEM : Component Parts Location"

.

Condition

Air passage continuity 

between  

and 

12 V direct current supply between 
terminals 1 and 2

Existed

No supply

Not existed

PBIB2059E

P0447 EVAP CANISTER VENT CONTROL VALVE

EC-305

< DTC/CIRCUIT DIAGNOSIS >

[VQ35DE]

C

D

E

F

G

H

I

J

K

L

M

A

EC

N

P

O

P0447 EVAP CANISTER VENT CONTROL VALVE

DTC Logic

INFOID:0000000009178212

DTC DETECTION LOGIC

DTC CONFIRMATION PROCEDURE

1.

PRECONDITIONING

If DTC Confirmation Procedure has been previously conducted, always perform the following before conduct-

ing the next test.

1. Turn ignition switch OFF and wait at least 10 seconds.

2. Turn ignition switch ON.

3. Turn ignition switch OFF and wait at least 10 seconds.

TESTING CONDITION:

Before performing the following procedure, confirm battery voltage is more than 11 V at idle.

>> GO TO 2.

2.

PERFORM DTC CONFIRMATION PROCEDURE

1. Start engine and wait at least 8 seconds.

2. Check 1st trip DTC.
Is 1st trip DTC detected?

YES

>> Proceed to 

EC-306, "Diagnosis Procedure"

.

NO

>> INSPECTION END

Diagnosis Procedure

INFOID:0000000009178213

1.

INSPECTION START

Will CONSULT be used?
Will CONSULT be used?

YES

>> GO TO 2.

NO

>> GO TO 3.

2.

CHECK EVAP CANISTER VENT CONTROL VALVE CIRCUIT

With CONSULT

1. Turn ignition switch OFF and then ON.

2. Select “VENT CONTROL/V” in “ACTIVE TEST” mode with CONSULT.

3. Touch “ON/OFF” on CONSULT screen.

4. Check for operating sound of the valve.

Is the inspection result normal?

YES

>> GO TO 6.

NO

>> GO TO 3.

3.

CHECK EVAP CANISTER VENT CONTROL VALVE POWER SUPPLY

1. Turn ignition switch OFF.

2. Disconnect EVAP canister vent control valve harness connector.

DTC No.

CONSULT screen terms

(Trouble diagnosis content)

DTC detecting condition

Possible cause

P0447

VENT CONTROL VALVE
(Evaporative emission sys-
tem vent control circuit open)

An improper voltage signal is sent to ECM 
through EVAP canister vent control valve.

• Harness or connectors

(The valve circuit is open or shorted.)

• EVAP canister vent control valve
• Hoses

(Hoses are connected incorrectly or 
clogged.)

Clicking sound should be heard.

 

 

 

 

 

 

 

Content   ..  497  498  499  500   ..