содержание .. 781 782 783 784 ..
P0190 FRP SENSOR EC-261 < DTC/CIRCUIT DIAGNOSIS > [MR20DD] C D E F G H I J K L M A EC N P O WITHOUT CONSULT 1. Turn ignition switch OFF. 2. Reconnect harness connector disconnected. 3. Start engine and warm it up to normal operating temperature. 4. Check FRP sensor signal voltage. Is inspection result normal? YES >> INSPECTION END NO >> Replace FRP sensor. Refer to ECM Condition Voltage Connector + − Terminal F7 33 39 [Engine is running] Approx. 0.82 – 1.14 V [Engine is running] Approx. 0.82 – 2.9 V |