содержание .. 469 470 471 472 ..
AUTOMATIC BACK DOOR OPERATION DOES NOT OPERATE DLK-225 < SYMPTOM DIAGNOSIS > [TYPE 1] C D E F G H I J L M A B DLK N O P INTELLIGENT KEY : Description INFOID:0000000010708192 Automatic back door open/close function does not operate using Intelligent Key. INTELLIGENT KEY : Diagnosis Procedure INFOID:0000000010708193 1. CHECK REMOTE KEYLESS ENTRY FUNCTION Check remote keyless entry function. Does door lock/unlock with Intelligent Key button? YES >> GO TO 2. NO >> Refer to DLK-239, "Diagnosis Procedure" 2. CHECK AUTO OPEN/CLOSE FUNCTION Check auto open/close function using automatic back door switch. Is the inspection result normal? YES >> GO TO 3. NO >> Refer to DLK-223, "ALL SWITCHES : Diagnosis Procedure" . 3. REPLACE INTELLIGENT KEY 1. Replace Intelligent Key. 2. Confirm the operation after replacement. Is the result normal? YES >> INSPECTION END NO >> GO TO 4. 4. REPLACE AUTOMATIC BACK DOOR CONTROL UNIT 1. Replace automatic back door control unit. Refer to DLK-327, "Removal and Installation" 2. Confirm the operation after replacement. Is the result normal? YES >> INSPECTION END NO >> Check intermittent incident. Refer to GI-44, "Intermittent Incident" . BACK DOOR OPENER SWITCH BACK DOOR OPENER SWITCH : Description INFOID:0000000010708194 Automatic back door open/close function does not operate using back door opener switch. BACK DOOR OPENER SWITCH : Diagnosis Procedure INFOID:0000000010708195 1. CHECK AUTO OPEN/CLOSE FUNCTION Check auto open/close function using automatic back door switch. Is the inspection result normal? YES >> GO TO 2. NO >> Refer to DLK-223, "ALL SWITCHES : Diagnosis Procedure" . 2. CHECK BACK DOOR OPENER SWITCH Check back door opener switch. DLK-168, "Component Function Check" Is the inspection result normal? YES >> GO TO 3. NO >> Repair or replace the malfunctioning parts. 3. REPLACE AUTOMATIC BACK DOOR CONTROL UNIT 1. Replace automatic back door control unit. Refer to DLK-327, "Removal and Installation" 2. Confirm the operation after replacement. Is the result normal? YES >> INSPECTION END |