BLEEDING ELECTRIC OIL PUMP TM-507 < BASIC INSPECTION > [CVT: RE0F10G] C E F G H I J K L M A B TM N O P BLEEDING ELECTRIC OIL PUMP Description INFOID:0000000010326094 The electric oil pump suctions oil from the oil pan through the sub-strainer. If air is contained in the sub- Work Procedure INFOID:0000000010326095 1. PREPARATION BEFORE WORK 1. Start the engine and warm it up. 2. After warm-up, stop the engine and wait for 60 seconds or more. >> GO TO 2. 2. BLEED ELECTRIC OIL PUMP With CONSULT 1. Turn ignition switch ON. CAUTION: Never start the engine. 2. Shift the selector lever to the P position. 3. Select “WORK SUPPORT” in “TRANSMISSION”. 4. Select “ELECTRIC O.P. AIR BLEEDING”. 5. Touch “Start”. CAUTION: Never start the engine during air bleeding. Is “COMPLETED” displayed? YES >> GO TO 3. NO >> Turn OFF the ignition switch and wait for 10 seconds or more. Then, start the work again. 3. CHECK THE COMPLETION OF BLEEDING ELECTRIC OIL PUMP (PART 1) With CONSULT 1. Start the engine. 2. Wait for 10 seconds. 3. Turn ignition switch OFF. 4. Wait for 10 seconds. 5. Turn ignition switch ON. CAUTION: Never start the engine. 6. Select “Data Monitor” in “TRANSMISSION”. 7. Select “AIR BLDING STATE”. Is “COMP” displayed? YES >> GO TO 4. NO >> Turn OFF the ignition switch and wait for 10 seconds or more. Then, start the work again. 4. CHECK THE COMPLETION OF BLEEDING ELECTRIC OIL PUMP (PART 2) 1. Start the engine. 2. Activate stop/start system. Refer to EC9-39, "STOP/START SYSTEM : System Description (M/T mod- Does the stop/start system start? YES >> WORK END NO >> Check DTC “P188F”. Refer to |