Content .. 1048 1049 1050 1051 ..
HA-26 < BASIC INSPECTION > [TYPE 1] PERFORMANCE TEST PERFORMANCE TEST Inspection INFOID:0000000010451976 INSPECTION PROCEDURE 1. Connect recovery/recycling/recharging equipment (for HFO-1234yf) or manifold gauge. 2. Start the engine, and set to the following condition. Test condition 3. Maintain test condition until A/C system becomes stable. (More than 15 minutes) 4. Check that test results of “recirculating-to-discharge air temperature” and “ambient air temperature-to- 5. When test results are within the specified value, inspection is complete. . RECIRCULATING-TO-DISCHARGE AIR TEMPERATURE TABLE AMBIENT AIR TEMPERATURE-TO-OPERATING PRESSURE TABLE Surrounding condition Indoors or in the shade (in a well-ventilated place) Vehicle condition Door Closed Door glass Full open Hood Open Engine speed Idle speed A/C condition Temperature control switch or dial Full cold A/C switch ON Air outlet VENT (ventilation) Intake door position Recirculation Fan speed Maximum speed set Inside air (Recirculating air) at blower assembly inlet Discharge air temperature from center ventilator ° C ( ° F) Relative humidity % Air temperature ° C ( ° F) 50 – 60 15 (59) 2.4 – 3.9 (36 – 39) 20 (68) 8.4 – 10.4 (47 – 51) 25 (77) 13.0 – 15.5 (55 – 66) 30 (86) 16.9 – 19.8 (62 – 68) 60 – 70 15 (59) 3.9 – 5.3 (39 – 42) 20 (68) 10.4 – 12.5 (51 – 55) 25 (77) 15.5 – 18.0 (60 – 64) 30 (86) 19.8 – 22.7 (68 – 73) |