WATER OUTLET CO-27 < REMOVAL AND INSTALLATION > [MR FOR NISMO RS MODELS] C D E F G H I J K L M A CO N P O • Place a thread (A) so that it is caught in the valves of water control valve (1). Immerse fully in a container (B) filled with water. Heat while stirring. • The valve opening temperature is the temperature at which the valve opens and falls from the thread. • Continue heating. Check the continuous valve lifting toward maxi- mum valve lift. NOTE: The maximum valve lift amount standard temperature for water control valve is the reference value. • After checking the maximum valve lift amount, lower the water temperature and check the valve closing temperature. • If out of the standard, replace water control valve. INSPECTION AFTER INSTALLATION • Check for leakage of engine coolant using the radiator cap tester adapter (commercial service tool) and the radiator cap tester (commercial service tool). Refer to • Start and warm up the engine. Check visually that there is no leakage of engine coolant. Standard: Refer to . PBIC3314J |